MLGQ25 HUSKER WITH ASPIRATOR FAQ

From:adminViews:Release time:2017-06-13

Condition of failure
Cause (in processing)remedy
Poor husking ratio
Insufficient roll pressure.Adjust the pressure to increase the pressure as to set the husking ratio at about 90% without any damage on the grain skin.
High water content of the paddy.Measure the water content, and adjust it to a right level.
Worn rollsIf the main shaft roll is smaller in diameter than the countershaft roll, exchange the right and left sides.
Replace them with new ones.
Excessive feed rate.Decrease feed rate using the feed rate adjusting handle.
Belt slippageTight belt as per 5,6,8.
much husk included in the husked rice
Maladjusted wind-sorting section.Adjust the valve.
Belt slippage.Tighten the belt.
Husking is often interrupted.Use the valve to decrease the feed rate, and avoid any long duration of interruption wherever possible.
Too much feed rate. Blocked louver.Clean the louver.
Des not power on (pilot lamp does not illuminate
The power switch of the paddy husker control panel is not turned on.Turn on the switch.
Broken cable.Check the conductance of power cable.
Blown fuse (F1) on the front of the control box.Replace the fuse(1A)
Rolls do not open/close.
Fault with the air cylinder (for rolls).Replace the air cylinder.
Fault with the speed controller.Replace the speed controller.
Fault with the regulator.Replace the regulator.
Excessive tension of the driving Hex.Adjust the belt tension.
Bolt, or wrong belt routing.Check the belt routing, and reinstall the belt if necessary.
Fault with the air valve.Replace the air valve.
Neither shutter nor rolls function.
Fault with the HAND/AUTO change over switch.Replace the switch
Blow fuse on the panel.Replace the fuse(1A).
No or sufficient air feed.Feed air 5kgf/cm²or more.
Fault with the solenoid valveReplace the solenoid valve.
Shutter does not open.
No paddy contained in the husker hopper.Supply the paddy.
The time set on the timer has not elapsed yet from the paddy began the accumulating.Wait until the time comes.
The paddy separator hopper is full.Wait unit the hopper becomes empty.
Fault protection circuit tripped.Repair the fault.
Fault with the husker hopper lower limit level gauge.Replace the level gauge.
Fault with the air cylinder.Replace the air cylinder.
Ball valve closed.Open the ball valve.
Low air pressure.Wait until the air pressure recovers.
Shutter does not close.
Fault with the upper limit level gauge of the paddy separator machine hopper.Replace the level gauge.
Low air pressure.Check and adjust the air pressure.
Fault with the air cylinder and solenoid valve.Replace the air cylinder and solenoid valve.